Features
Non-invasive transducers are easy to install, cost effective, and require no pipe cutting or processing interrupt.
Wide liquid temperature range: -35℃~200℃.
Data logger function.
Thermal energy measurement capability can be optional.
For commonly used pipe materials and diameters from 20mm to over 6000m.
Wide bi-directional flow range of 0.01 m/s to 12 m/s.
Specificaitons
Transmitter:
| Measurement principle | Ultrasonic transit-time difference correlation principle |
| Flow velocity range | 0.01 to 12 m/s, bi-directional |
| Resolution | 0.25mm/s |
| Repeatability | 0.2% of reading |
| Accuracy | ±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s |
| Response time | 0.5s |
| Sensitivity | 0.003m/s |
| Damping of displayed value | 0-99s(selectable by user) |
| Liquid Types Supported | both clean and somewhat dirty liquids with turbidity <10000 ppm |
| Power Supply | AC: 85-265V DC: 24V/500mA |
| Enclosure type | Wall-mounted |
| Degree of protection | IP66 according to EN60529 |
| Operating temperature | -20℃ to +60℃ |
| Housing material | Fiberglass |
| Display | 4 line×16 English letters LCD graphic display, backlit |
| Units | User Configured (English and Metric) |
| Rate | Rate and Velocity Display |
| Totalized | gallons, ft³, barrels, lbs, liters, m³,kg |
| Thermal energy | unit GJ,KWh can be optional |
| Communication | 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger |
| Security | Keypad lockout, system lockout |
| Size | 244*196*114mm |
| Weight | 2.4kg |
Transducer:
| Degree of protection | IP65 according to EN60529.(IP67 or IP68 Upon request) |
| Suited Liquid Temperature | Std. Temp.: -35℃~85℃ for short periods up to 120℃ |
| High Temp.: -35℃~200℃ for short periods up to 250℃ | |
| Pipe diameter range | 20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L |
| Transducer Size | Type S 48(h)*28(w)*28(d)mm |
| Type M 60(h)*34(w)*32(d)mm | |
| Type L 80(h)*40(w)*42(d)mm | |
| Material of transducer | Aluminum (standard temperature), and peek (high temperature) |
| Cable Length | Std:10m |
| Temperature Sensor | Pt1000 Clamp-on Accuracy: ±0.1% |
Configuration Code
| TF1100-EC | Wall-mounted Transit-time Clamp-on Ultrasonic Flowmeter | |||||||||||||||||||||||
| Power supply | ||||||||||||||||||||||||
| A | 85-265VAC | |||||||||||||||||||||||
| D | 24VDC | |||||||||||||||||||||||
| S | 65W Solar supply | |||||||||||||||||||||||
| Output Selection 1 | ||||||||||||||||||||||||
| N | N/A | |||||||||||||||||||||||
| 1 | 4-20mA (accuracy 0.1%) | |||||||||||||||||||||||
| 2 | OCT | |||||||||||||||||||||||
| 3 | Relay Output (Totalizer or Alarm) | |||||||||||||||||||||||
| 4 | RS232 Output | |||||||||||||||||||||||
| 5 | RS485 Output (ModBus-RTU Protocol) | |||||||||||||||||||||||
| 6 | Data storage fuction | |||||||||||||||||||||||
| 7 | GPRS | |||||||||||||||||||||||
| Output Selection 2 | ||||||||||||||||||||||||
| Same as above | ||||||||||||||||||||||||
| Output Selection 3 | ||||||||||||||||||||||||
| Transducer Type | ||||||||||||||||||||||||
| S | DN20-50 | |||||||||||||||||||||||
| M | DN40-1000 | |||||||||||||||||||||||
| L | DN1000-6000 | |||||||||||||||||||||||
| Transducer Rail | ||||||||||||||||||||||||
| N | None | |||||||||||||||||||||||
| RS | DN20-50 | |||||||||||||||||||||||
| RM | DN40-600 (For larger pipe size, pls contact us.) | |||||||||||||||||||||||
| Transducer Temperature | ||||||||||||||||||||||||
| S | -35~85℃ (for short periods up to 120℃) | |||||||||||||||||||||||
| H | -35~200℃ (Only for S.M sensor.) | |||||||||||||||||||||||
| Temperature Input Sensor | ||||||||||||||||||||||||
| N | None | |||||||||||||||||||||||
| T | Clamp-on PT1000 | |||||||||||||||||||||||
| Pipeline Diameter | ||||||||||||||||||||||||
| DNX | e.g.DN20—20mm, DN6000—6000mm | |||||||||||||||||||||||
| Cable length | ||||||||||||||||||||||||
| 10m | 10m (standard 10m) | |||||||||||||||||||||||
| Xm | Common cable Max 300m(standard 10m) | |||||||||||||||||||||||
| XmH | High temp. cable Max 300m | |||||||||||||||||||||||
| TF1100-EC | — | A | — | 1 | — | 2 | — | 3 | /LTC— | M | — | N | — | S | — | N | — | DN100 | — | 10m | (example configuration) | |||
Applications
● Service and maintenance
● Replacement of defective devices
● Support of commissioning process and installation
● Performance and efficiency measurement
- Evaluation and assessments
- Capacity measurement of pumps
- Monitoring of regulating valves
● Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
● Petrochemical industry
● Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
● Refrigeration and air conditioning systems
● Food , beverage and pharmaceutical industry
● Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc
● Metallurgy and mining applications
● Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.