Factory Supply Open Channel Hydraulics Equations - Partially Filled Pipe & Open Channel Flowmeter DOF6000 – Lanry Detail:
Description
Features
Specificaitons
Installation
Applications
Ultrasonic Doppler Principle in Quadrature Sampling Mode is utilised to measure water velocity. The 6537 Instrument transmits ultrasonic energy through its epoxy casing into the water. Suspended sediment particles, or small gas bubbles in the water reflect some of the transmitted ultrasonic energy back to the 6537 Instrument’s ultrasonic receiver instrument that processes this received signal and calculates the water velocity.
Water depth is measured with two methods. An ultrasonic depth sensor measures water depth using the ultrasonic principle from a top mounted sensor on the instrument. Depth is also measured using the pressure principle from a bottom mounted sensor in the instrument. These two sensors provide flexibility in depth measurement. Some applications, for example measuring from the side of a pipe, better suits a pressure principle, while other applications in clear open channels better suit an ultrasonic principle.
The QSD6537 Sensor has a 4 electrodes conductivity instrument (EC) included to measure the quality of the water, with four electrodes exposed to the water at the top of the instrument. Water quality is measured on an ongoing basis and this parameter can be recorded along with velocity and depth to better analyse the nature of the water in open channels and pipes.
Features

Velocity Range: 0.02mm/s to 12m/s bi-directional, accuracy is 1%.

Depth Range: 0 to 10m.

Measure velocity in both forward flow and back flow.

Depth is measured by both the pressure sensor and ultrasonic level sensor principles.

With borometric and pressure compensation function.

IP68 Epoxy-sealed body design, designed under water installation.

RS485/MODBUS output, connect to computer directly.
Specificaitons
Sensor:
| Velocity | Velocity range: | 20mm/sec to 12 m/sec Bidirectional velocity capability, set using configuration tools |
| Velocity accuracy: | ±1 % measured velocity | |
| Velocity resolution: | 1 mm/s | |
| Depth (Ultrasonic) | Range: | 20mm to 5000mm (5m) |
| Accuracy: | ± 1 % measured | |
| Resolution: | 1 mm | |
| Depth (Pressure) | Range: | 0mm to 10000mm (10m) |
| Accuracy: | ± 1 % measured | |
| Resolution: | 1 mm | |
| Temperature | Range: | 0°C to 60°C |
| Accuracy: | ±0.5°C | |
| Resolution: | o.1°C | |
| Electrical Conductivity (EC) | Range: | 0 to 200,000 |iS/cm, Typically ± 1 % of measurement |
| Resolution | ±1 µS/cm | |
| May be recorded as a 16-bit value (0 to 65,535 p.S/cm) or a 32-bit value (0 to 262,143 uS/cm) | ||
| Tilt (Accelerometer) | Range: | ±70° in roll and pitch axes. |
| Accuracy: | ±1 ° for angles less than 45° | |
| Output | SDI-12: | SDI-12 v1.3, Max. cable 50m |
| RS485: | Modbus RTU, Max. cable 500m | |
| Environmental | Operating temperature: | 0°C 〜+60°C water temperature |
| Storage temperature: | -20°C 〜+60°C | |
| IP class: | IP68 | |
| Others | Cable: | The standard cable is 15m, the maximum option is 500m. |
| Sensor material: | Epoxy-sealed body, Marine Grade 316 Stainless Steel Mounting Bracket | |
| Sensor size: | 135mm x 50mm x 20mm (L x W x H) | |
| Sensor weight: | 1 kg with 15m of cable | |
Caculator:
|
Type: |
Portable |
|
Power supply: |
Calculator: 85-265VAC(Charging battery) |
|
IP class: |
Calculator: IP66 |
|
Operating temperature: |
0°C ~+60°C |
|
Case material: |
ABS |
|
Display: |
4.5″ color LCD |
|
Output: |
Pulse, 4-20mA (Flow & Depth), RS485/Modbus, Datalogger, GPRS |
|
Size: |
270Lx215Wx175H (mm) |
|
Weight: |
3 kg |
|
Data storage: |
16GB |
|
Application: |
Partially Filled Pipe: 150-6000mm; Channel: width >200mm |
Installation Details

Partially Filled Pipe

Pipe with Siltation on Bottom

V-notch Shape Channel

Rectangular channel

Pre-formed Two-stage Rectangular Channel

Natrual Stream
Applications

Power Plants

Irrigation & Drainage

River Discharge

Flood Monitoring & Flood Alerts

Rivers and Streams Monitoring

Surface Water Monitoring

Industrial Outflow Monitoring

Wastewater Treatment Plant

Rainwater Measurement

Sewage Treatment

Hydrological Monitoring

Water Supply




Product detail pictures:

Related Product Guide:
Our company since its inception, constantly regards product or service high quality as business life, continually improve creation technology, make improvements to product high-quality and consistently strengthen business total high-quality management, in strict accordance together with the national standard ISO 9001:2000 for Factory Supply Open Channel Hydraulics Equations - Partially Filled Pipe & Open Channel Flowmeter DOF6000 – Lanry, The product will supply to all over the world, such as: Sevilla, panama, Egypt, We welcome you to visit our company & factory and our showroom displays various products that will meet your expectations. Meanwhile, it is convenient to visit our website. Our sales staff will try their best to provide you with the best services. If you need more information, please do not hesitate to contact us via E-mail, fax or telephone.
The factory technical staff gave us a lot of good advice in the cooperation process, this is very good, we are very grateful.
-
PriceList for Flowmeters For Water - Ultrawate...
-
China OEM Nb Iot Water Meter - WM9100-EV Prepa...
-
Discount Price Water Well Flow Meter - Ultrawa...
-
8 Year Exporter Flow Meters For Sewer Line - T...
-
Cheapest Factory Sewage Meters For Residential ...
-
OEM/ODM Supplier Flow Meter Factory - Insertio...