Massive Selection for Water Flow Sensor - WM9100-ED Residential Ultrasonic Water Meter – Lanry Detail:
Description
Features
Technical Parameter
Residential ultrasonic water meter is used for measuring and display water flow.
Nominal Diameter: DN15~DN25
Product Features

With functions of self-diagnosis, flow sensor Alarm, Temperature Sensor Alarm, Over Range Alarm and battery under voltage alarm

With optic electric interface, hand-held infrared meter reading tool can read directly

Built-in wireless nb-iot

Stainless steel 316l is optional, meet the measurement of direct drinking water

Bi-directional measuring forward and reverse flow

According to sanitary standard for drinking water
Technical Parameter
| Max. Working Pressure | 1.6Mpa |
| Temperature Class | T30 |
| Accuracy Class | ISO 4064, Accuracy Class 2 |
| Body Material | Stainless SS304(opt. SS316L) |
| Battery Life | 6 Years(Consumption≤0.3mW) |
| Protection Class | IP68 |
| Environmental Temperature | -40~+70℃,≤100%RH |
| Pressure Loss | ΔP25(Based on different dynamic flow) |
| Climatic And Mechanical Environment | Class O |
| Electromagnetic Class | E2 |
| Communication | Wired M-bus, RS485; Wireless LoRaWAN |
| Display | 9 digits LCD display volume, flow rate, power alarm, flow direction, output etc. |
| Connection | Thread |
| Flow Profile Sensitivity Class | U5/D3 |
| Data Storage | Store the latest 24 years’ data including day, month and year, The data can be permanently saved even powered off |
| Frequency | 1-4 times/second |
Digital Display

![]()
Measuring Range and Dimensions(R250)
| Nominal Diameter | Permanent Flow Q3 | Transitional FlowQ2 | Minimum Flow Q1 | Installation without connection accessories(A) | Installation with connection accessories(B) | L | L1 | H | Length of connection accessories(S) | W |
| DN(mm) | (m3/h) | (m3/h) | (m3/h) | mm | mm | mm | mm | mm | ||
| 15 | 2.5 | 0.016 | 0.010 | G¾B | R½ | 165 | 135 | 82 | 53.8 | 96 |
| 20 | 4.0 | 0.026 | 0.016 | G1B | R¾ | 195 | 157 | 90 | 60 | 100 |
| 25 | 6.3 | 0.040 | 0.025 | G1¼B | R1 | 225 | 165 | 96 | 70 | 100 |
Measuring Range and Dimensions(R400)
| Nominal Diameter | Permanent Flow Q3 | Transitional FlowQ2 | Minimum Flow Q1 | Installation without connection accessories(A) | Installation with connection accessories(B) | L | L1 | H | Length of connection accessories(S) | W |
| DN(mm) | (m3/h) | (m3/h) | (m3/h) | mm | mm | mm | mm | mm | ||
| 15 | 2.5 | 0.016 | 0.006 | G¾B | R½ | 165 | 135 | 82 | 53.8 | 96 |
| 20 | 4.0 | 0.026 | 0.010 | G1B | R¾ | 195 | 157 | 90 | 60 | 100 |
| 25 | 6.3 | 0.040 | 0.016 | G1¼B | R1 | 225 | 165 | 96 | 70 | 100 |
Product detail pictures:

Related Product Guide:
Our well-equipped facilities and exceptional good quality manage throughout all stages of production enables us to guarantee total shopper satisfaction for Massive Selection for Water Flow Sensor - WM9100-ED Residential Ultrasonic Water Meter – Lanry, The product will supply to all over the world, such as: Kazakhstan, UK, Vietnam, Our products have won an excellent reputation at each of the related nations. Because the establishment of our firm. we have insisted on our production procedure innovation together with the most recent modern day managing method, attracting a sizable quantity of talents within this industry. We regard the solution good quality as our most vital essence character.
The sales person is professional and responsible, warm and polite, we had a pleasant conversation and no language barriers on communication.
-
Hot-selling Ultrasonic Flow Transducer - Porta...
-
Factory making Sanitary Sewer Flow Monitoring -...
-
2021 wholesale price Area Flow Meter - Wall-mo...
-
Well-designed Flow Meter For Hot Water - clamp...
-
Manufacturer for Ultrasonic Flow Detector - Po...
-
Reliable Supplier Non Invasive Flow Meter - Ha...
Send your message to us:
Write your message here and send it to us