Ultrasonic Flow Meters

20+ Years Manufacturing Experience

new products

  • Ultrasonic Water Meter Lcd Display Flow Meter Flowmeter Modbus/Lora/Lorawan/Gsm/Nb-iot Smart Digital Ultrasonic Water Meter

    Ultrasonic Water Meter Lcd Display Flow Meter Flowmeter Modbus/Lora/Lorawan/Gsm/Nb-iot Smart Digital Ultrasonic Water Meter

    Direct reading ultrasonic water meter is used for measuring, storage and display water flow.
    Nominal Diameter: DN15~DN40
    Application range: Tap-water pipe net system

  • parshall flume flow meter for waste water

    parshall flume flow meter for waste water

    UOL serials is non-contact ultrasonic open channel flow meter, with low blind area, high sensitivity, high stability. It consists of ultrasonic probe and the host, mainly used for measuring water conservancy irrigation, sewage plants, enterprises and institutions of the flow rate of the sewage outfalls, urban sewage and chemical enterprise part of the flow measurement.

  • Handheld Portable Ultrasonic Flow Meter Water Flowmeter With Clamp On Sensor

    Handheld Portable Ultrasonic Flow Meter Water Flowmeter With Clamp On Sensor

    TF1100-CH Handheld Ultrasonic Flow Meter works on the transit-time method. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges.

    User can use hand to hold as well as to operate the flow meter main unit. This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

  • RS485 Modbus clamp on ultrasonic flow meter btu meter wall-mounted for metallurgy

    RS485 Modbus clamp on ultrasonic flow meter btu meter wall-mounted for metallurgy

    TF1100-EC Wall-mounted Transit Time Ultrasonic Flowmeter works on the transit-time method. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.

    This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

  • data logger and RS485 modbus open channel flow meter for not full pipe

    data logger and RS485 modbus open channel flow meter for not full pipe

    The DOF6000 series flowmeter consists of Flow calculator and the Ultraflow QSD 6537 sensor.

    The Ultraflow QSD 6537 Sensor is used to measure water velocity, depth, and conductivity of water flowing in rivers, streams, open channels and pipes.

    When used with a companion Lanry DOF6000 Calculator, flow rate and total flow can also be calculated.

    The flow calculator can calculate the cross-sectional area of partially filled pipe, open channel stream or river, for stream or river, with up to 20 coordinate points describing the river’s shape of cross section. It is suitable for various applications.

    Ultrasonic Doppler Principle in Quadrature Sampling Mode is utilised to measure water velocity. The 6537 Instrument transmits ultrasonic energy through its epoxy casing into the water. Suspended sediment particles, or small gas bubbles in the water reflect some of the transmitted ultrasonic energy back to the 6537 Instrument’s ultrasonic receiver instrument that processes this received signal and calculates the water velocity.

  • Doppler portable handheld ultrasonic flow meter for ground water

    Doppler portable handheld ultrasonic flow meter for ground water

    Series DF6100-EP Doppler Portable Ultrasonic Flow Meter is designed to measure volumetric flow of within closed conduit, the pipe line must be full of liquids, and there must be a certain amount of air bubbles or suspended solids in liquid.

     

    The Doppler ultrasonic flow meter can display flow rate and flow totalizer, etc., and is configured with 4-20mA, OCT outputs.

  • clamp-on digital RS485 modbus ultrasonic flowmeter

    clamp-on digital RS485 modbus ultrasonic flowmeter

    TF1100-EC Wall-mounted Transit Time Ultrasonic Flowmeter works on the transit-time method. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.

    This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

  • portable ultrasonic flow meter liquid for pure water and milk

    portable ultrasonic flow meter liquid for pure water and milk

    The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.

     

    This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

  • portable open channel flow meter doppler area-velocity with 20 coordinate points

    portable open channel flow meter doppler area-velocity with 20 coordinate points

    The DOF6000 series flowmeter consists of Flow calculator and the Ultraflow QSD 6537 Sensor.

    The Ultraflow QSD 6537 Sensor is used to measure water velocity, depth, and conductivity of water flowing in rivers, streams, open channels and pipes. When used with a companion Lanry DOF6000 Calculator, flow rate and total flow can also be calculated.
    The flow calculator can calculate the cross-sectional area of partially filled pipe, open channel stream or river, for stream or river, with up to 20 coordinate points describing the river’s shape of cross section. It is suitable for various applications.

  • DF6100-EC wall mounted clamp-on ultrasonic doppler flowmeter

    DF6100-EC wall mounted clamp-on ultrasonic doppler flowmeter

    DF6100-EC Wall-mounted Doppler Ultrasonic Flow Meter is designed to measure volumetric flow of liquid within closed conduit, the pipe line must be full of liquids, and there must be a certain amount of air bubbles or suspended solids in liquid.

    The Doppler ultrasonic flow meter can display flow rate and flow totalizer, etc., and is configured with 4-20mA, Relays,OCT outputs.

  • fixed type clamp-on doppler ultrasonic flowmeter for raw sewage

    fixed type clamp-on doppler ultrasonic flowmeter for raw sewage

    DF6100-EC Wall-mounted Doppler Ultrasonic Flow Meter is designed to measure volumetric flow of liquid within closed conduit, the pipe line must be full of liquids, and there must be a certain amount of air bubbles or suspended solids in liquid.

    The Doppler ultrasonic flow meter can display flow rate and flow totalizer, etc., and is configured with 4-20mA, Relays,OCT outputs.

  • Portable Type Doppler Flowmeter For Paper Slurry

    Portable Type Doppler Flowmeter For Paper Slurry

    Series DF6100-EP Doppler Portable Ultrasonic Flow Meter is designed to measure volumetric flow of within closed conduit, the pipe line must be full of liquids, and there must be a certain amount of air bubbles or suspended solids in liquid.

     

    The Doppler ultrasonic flow meter can display flow rate and flow totalizer, etc., and is configured with 4-20mA, OCT outputs.

Send your message to us: