PriceList for Open Channel Flow Measurement Devices - Partially Filled Pipe & Open Channel Flowmeter DOF6000 – Lanry Detail:
Description
Features
Specificaitons
Installation
Applications
Ultrasonic Doppler Principle in Quadrature Sampling Mode is utilised to measure water velocity. The 6537 Instrument transmits ultrasonic energy through its epoxy casing into the water. Suspended sediment particles, or small gas bubbles in the water reflect some of the transmitted ultrasonic energy back to the 6537 Instrument’s ultrasonic receiver instrument that processes this received signal and calculates the water velocity.
Water depth is measured with two methods. An ultrasonic depth sensor measures water depth using the ultrasonic principle from a top mounted sensor on the instrument. Depth is also measured using the pressure principle from a bottom mounted sensor in the instrument. These two sensors provide flexibility in depth measurement. Some applications, for example measuring from the side of a pipe, better suits a pressure principle, while other applications in clear open channels better suit an ultrasonic principle.
The QSD6537 Sensor has a 4 electrodes conductivity instrument (EC) included to measure the quality of the water, with four electrodes exposed to the water at the top of the instrument. Water quality is measured on an ongoing basis and this parameter can be recorded along with velocity and depth to better analyse the nature of the water in open channels and pipes.
Features

Velocity Range: 0.02mm/s to 12m/s bi-directional, accuracy is 1%.

Depth Range: 0 to 10m.

Measure velocity in both forward flow and back flow.

Depth is measured by both the pressure sensor and ultrasonic level sensor principles.

With borometric and pressure compensation function.

IP68 Epoxy-sealed body design, designed under water installation.

RS485/MODBUS output, connect to computer directly.
Specificaitons
Sensor:
| Velocity | Velocity range: | 20mm/sec to 12 m/sec Bidirectional velocity capability, set using configuration tools |
| Velocity accuracy: | ±1 % measured velocity | |
| Velocity resolution: | 1 mm/s | |
| Depth (Ultrasonic) | Range: | 20mm to 5000mm (5m) |
| Accuracy: | ± 1 % measured | |
| Resolution: | 1 mm | |
| Depth (Pressure) | Range: | 0mm to 10000mm (10m) |
| Accuracy: | ± 1 % measured | |
| Resolution: | 1 mm | |
| Temperature | Range: | 0°C to 60°C |
| Accuracy: | ±0.5°C | |
| Resolution: | o.1°C | |
| Electrical Conductivity (EC) | Range: | 0 to 200,000 |iS/cm, Typically ± 1 % of measurement |
| Resolution | ±1 µS/cm | |
| May be recorded as a 16-bit value (0 to 65,535 p.S/cm) or a 32-bit value (0 to 262,143 uS/cm) | ||
| Tilt (Accelerometer) | Range: | ±70° in roll and pitch axes. |
| Accuracy: | ±1 ° for angles less than 45° | |
| Output | SDI-12: | SDI-12 v1.3, Max. cable 50m |
| RS485: | Modbus RTU, Max. cable 500m | |
| Environmental | Operating temperature: | 0°C 〜+60°C water temperature |
| Storage temperature: | -20°C 〜+60°C | |
| IP class: | IP68 | |
| Others | Cable: | The standard cable is 15m, the maximum option is 500m. |
| Sensor material: | Epoxy-sealed body, Marine Grade 316 Stainless Steel Mounting Bracket | |
| Sensor size: | 135mm x 50mm x 20mm (L x W x H) | |
| Sensor weight: | 1 kg with 15m of cable | |
Caculator:
|
Type: |
Portable |
|
Power supply: |
Calculator: 85-265VAC(Charging battery) |
|
IP class: |
Calculator: IP66 |
|
Operating temperature: |
0°C ~+60°C |
|
Case material: |
ABS |
|
Display: |
4.5″ color LCD |
|
Output: |
Pulse, 4-20mA (Flow & Depth), RS485/Modbus, Datalogger, GPRS |
|
Size: |
270Lx215Wx175H (mm) |
|
Weight: |
3 kg |
|
Data storage: |
16GB |
|
Application: |
Partially Filled Pipe: 150-6000mm; Channel: width >200mm |
Installation Details

Partially Filled Pipe

Pipe with Siltation on Bottom

V-notch Shape Channel

Rectangular channel

Pre-formed Two-stage Rectangular Channel

Natrual Stream
Applications

Power Plants

Irrigation & Drainage

River Discharge

Flood Monitoring & Flood Alerts

Rivers and Streams Monitoring

Surface Water Monitoring

Industrial Outflow Monitoring

Wastewater Treatment Plant

Rainwater Measurement

Sewage Treatment

Hydrological Monitoring

Water Supply




Product detail pictures:

Related Product Guide:
Our business puts emphasis over the administration, the introduction of talented staff, plus the construction of employees building, striving hard to boost the standard and liability consciousness of staff members. Our corporation successfully attained IS9001 Certification and European CE Certification of PriceList for Open Channel Flow Measurement Devices - Partially Filled Pipe & Open Channel Flowmeter DOF6000 – Lanry, The product will supply to all over the world, such as: Barbados, Dubai, Vancouver, Merchandise have been exported to Asia, Mid-east,European and Germany market. Our company has constantly been able to update the items performance and safety to meet the markets and strive to be top A on stable quality and sincere service. If you have the honor to do business with our company. we'll undoubtedly do our very best to support your business in China.
In China, we have purchased many times, this time is the most successful and most satisfactory, a sincere and realiable Chinese manufacturer!
-
Super Lowest Price Ultrasonic Non Intrusive Flo...
-
China Supplier Insert Flowmeter - Insertion Tr...
-
Chinese wholesale Digital Water Flow Meter - S...
-
Big Discount Portable Clamp On Ultrasonic Flow ...
-
100% Original Factory Sanitary Sewer Flow Meter...
-
Factory Supply Open Channel Hydraulics Equation...