PriceList for Open Channel Flow Measurement Devices - Partially Filled Pipe & Open Channel Flowmeter DOF6000 – Lanry Detail:
Description
Features
Specificaitons
Installation
Applications
Ultrasonic Doppler Principle in Quadrature Sampling Mode is utilised to measure water velocity. The 6537 Instrument transmits ultrasonic energy through its epoxy casing into the water. Suspended sediment particles, or small gas bubbles in the water reflect some of the transmitted ultrasonic energy back to the 6537 Instrument’s ultrasonic receiver instrument that processes this received signal and calculates the water velocity.
Water depth is measured with two methods. An ultrasonic depth sensor measures water depth using the ultrasonic principle from a top mounted sensor on the instrument. Depth is also measured using the pressure principle from a bottom mounted sensor in the instrument. These two sensors provide flexibility in depth measurement. Some applications, for example measuring from the side of a pipe, better suits a pressure principle, while other applications in clear open channels better suit an ultrasonic principle.
The QSD6537 Sensor has a 4 electrodes conductivity instrument (EC) included to measure the quality of the water, with four electrodes exposed to the water at the top of the instrument. Water quality is measured on an ongoing basis and this parameter can be recorded along with velocity and depth to better analyse the nature of the water in open channels and pipes.
Features

Velocity Range: 0.02mm/s to 12m/s bi-directional, accuracy is 1%.

Depth Range: 0 to 10m.

Measure velocity in both forward flow and back flow.

Depth is measured by both the pressure sensor and ultrasonic level sensor principles.

With borometric and pressure compensation function.

IP68 Epoxy-sealed body design, designed under water installation.

RS485/MODBUS output, connect to computer directly.
Specificaitons
Sensor:
| Velocity | Velocity range: | 20mm/sec to 12 m/sec Bidirectional velocity capability, set using configuration tools |
| Velocity accuracy: | ±1 % measured velocity | |
| Velocity resolution: | 1 mm/s | |
| Depth (Ultrasonic) | Range: | 20mm to 5000mm (5m) |
| Accuracy: | ± 1 % measured | |
| Resolution: | 1 mm | |
| Depth (Pressure) | Range: | 0mm to 10000mm (10m) |
| Accuracy: | ± 1 % measured | |
| Resolution: | 1 mm | |
| Temperature | Range: | 0°C to 60°C |
| Accuracy: | ±0.5°C | |
| Resolution: | o.1°C | |
| Electrical Conductivity (EC) | Range: | 0 to 200,000 |iS/cm, Typically ± 1 % of measurement |
| Resolution | ±1 µS/cm | |
| May be recorded as a 16-bit value (0 to 65,535 p.S/cm) or a 32-bit value (0 to 262,143 uS/cm) | ||
| Tilt (Accelerometer) | Range: | ±70° in roll and pitch axes. |
| Accuracy: | ±1 ° for angles less than 45° | |
| Output | SDI-12: | SDI-12 v1.3, Max. cable 50m |
| RS485: | Modbus RTU, Max. cable 500m | |
| Environmental | Operating temperature: | 0°C 〜+60°C water temperature |
| Storage temperature: | -20°C 〜+60°C | |
| IP class: | IP68 | |
| Others | Cable: | The standard cable is 15m, the maximum option is 500m. |
| Sensor material: | Epoxy-sealed body, Marine Grade 316 Stainless Steel Mounting Bracket | |
| Sensor size: | 135mm x 50mm x 20mm (L x W x H) | |
| Sensor weight: | 1 kg with 15m of cable | |
Caculator:
|
Type: |
Portable |
|
Power supply: |
Calculator: 85-265VAC(Charging battery) |
|
IP class: |
Calculator: IP66 |
|
Operating temperature: |
0°C ~+60°C |
|
Case material: |
ABS |
|
Display: |
4.5″ color LCD |
|
Output: |
Pulse, 4-20mA (Flow & Depth), RS485/Modbus, Datalogger, GPRS |
|
Size: |
270Lx215Wx175H (mm) |
|
Weight: |
3 kg |
|
Data storage: |
16GB |
|
Application: |
Partially Filled Pipe: 150-6000mm; Channel: width >200mm |
Installation Details

Partially Filled Pipe

Pipe with Siltation on Bottom

V-notch Shape Channel

Rectangular channel

Pre-formed Two-stage Rectangular Channel

Natrual Stream
Applications

Power Plants

Irrigation & Drainage

River Discharge

Flood Monitoring & Flood Alerts

Rivers and Streams Monitoring

Surface Water Monitoring

Industrial Outflow Monitoring

Wastewater Treatment Plant

Rainwater Measurement

Sewage Treatment

Hydrological Monitoring

Water Supply




Product detail pictures:

Related Product Guide:
Adhering into the theory of "quality, services, efficiency and growth", now we have gained trusts and praises from domestic and international shopper for PriceList for Open Channel Flow Measurement Devices - Partially Filled Pipe & Open Channel Flowmeter DOF6000 – Lanry, The product will supply to all over the world, such as: Iran, Belize, French, With the development of the society and economy, our company will continue the "loyalty, dedication, efficiency, innovation" spirit of enterprise, and we will always adhere to the management idea of "would rather lose gold, do not lose customers heart". We will serve the domestic and foreign businessmen with sincere dedication, and let us create bright future together with you!
The factory workers have rich industry knowledge and operational experience, we learned a lot in working with them,we are extremely grateful that we can encount a good company has excellent wokers.
-
Factory selling Precision Flow Meter - Wall-mo...
-
Renewable Design for Insertion Flow Meter - Tr...
-
factory low price Portable Ultrasonic Heat Mete...
-
Original Factory Portable Ultrasonic Flow Meter...
-
Good quality Handheld Water Velocity Meter - U...
-
China Cheap price Flow Measurement In Open Chan...