Area velocity doppler flow meter
DOF6000 serial area velocity flow meter can monitor flow in any shapes of open channel, not full sewer or wastewater pipes without flume or weir. It is ideal for storm water, municipal water treatment and monitor, effluent, raw sewage, irrigation, running water, treated sewage water, etc . A suit...Read more -
Hydrologic QSD6537 Ultrasonic area velocity sensor
Only QSD6537 sensor is a submerged doppler sensor to continuously measure flow rate , depth, conductivity in open channels, partially filled pipes, rivers, streams, culverts, canals and others . It is designed for sewage, stormwater and stream flow applications. QSD6537 Area-Velocity Flow Meter ...Read more -
TRANSDUCER CABLES
After the transducers A and B inserting into the pipe, the sensor cables should be routed to the transmitter location. Verify that the supplied cable length is sufficient to meet the installation requirements. While transducer cable extension is not generally recommended, if additional transducer...Read more -
TRANSDUCER INSTALLATION PROCEDURES
Locate the reference mounting positions of 3 and 9 o’clock (180° symmetrically) as shown in Fig 3.1. Two transducers called A and B transducer, A is transmitting transducer and B is receiving transducer, they must be installed 180° symmetrically in order to have a more accurate measuring, shown ...Read more -
LMU serial ultrasonic level meter
LMU series is an compact 2-wire series ultrasonic level instrument for continuous non-contact level measurement in liquids and solids. It consists of probe and electronic units, both of which are leak-proof structure. This series can be widely applied to the metallurgical, chemical, electricity ...Read more -
Installation for LMU ultrasonic level meter
1. general hintsInstallation must be carried out by trained person in accordance with the manual. The temperature of the process may not exceed 75℃,and the pressure may not exceed -0.04~+0.2MPa. The use of metallic fittings or flanges is not recommended. For exposed or sunny locations a protect...Read more -
RC82 heat meter features
Ultrasonic heat BTU meter For Large Diameter Pipe 1. calculator can be hung at the body or installed separately. 2. Internal 3.6V high capacity lithium battery,external AC220V or DC24V optional; 3. Unique design for fluid structure to improve measuring accuracy and stability and reduce the requi...Read more -
DF6100-EC clamp on doppler flow meter transmitter installation
Mount the clamp on wastewater flow meter transmitter in a location that is: 1. Where little vibration exists 2. Protected from falling corrosive fluids 3. Within ambient temperature limits -20 to +60°C 4. Out of direct sunlight. Direct sunlight may increase transmitter temperature to above the ma...Read more -
Industrial transit-time ultrasonic flow meter for clean and pure water solution
At present, all of our Transit-Time ultrasonic flow meters are used for liquid flow measurement and The measured pipe must be full water pipe. Transit time liquid flow meter often used in water supply plants, HVAC application, pharmaceutical factory, food factory, beverage industry, metallurgy in...Read more -
Install Important Tips for SC7 serial flange type water meter
1. Pay attention to the seal to prevent leakage. 2. To pay attention to the instrument’s direction must be consistent with the actual flow direction 3. Note not let the gasket protruding into the pipe after the installation 4. The instrument is installed in the open pipe valve, pay particul...Read more -
Installation steps for SC7 serial ultrasonic water meter
To cut off the installation instrument place of water supply pipe, Set aside installation position of meter and threaded for union. Keep the threaded for union screwed to the water supply pipe opening. Align the instrument with the connection accessories;use Matching seal ring between instrument...Read more -
Several common error installation methods for SC7 serial ultrasonic smart water meter
1. When installation, please screw the pipe nut with a wrench. Do not use hand holding the plastic box body of calculator and then use the wrench to tighten the nut, because it may cause damage. 2. At a vertical installation scenario the heat meter needs to be installed on the flow upward stra...Read more