Ultrasonic heat meter-Principle of heat calculation

Principle of heat calculation: The ultrasonic heat meter measures the inlet and outlet temperatures of the heat-carrying liquid in the heat exchange loop by installing temperature sensors on the pipeline. Combining with the previously measured flow data, the heat is calculated according to the heat calculation formula Q=K×ρ×V×ΔT. Where Q represents the heat, K is a constant related to the structure of the heat meter and the characteristics of the fluid, ρ is the density of the fluid, V is the volumetric flow rate of the fluid, and ΔT is the temperature difference between the inlet and outlet fluids. Through this formula, the amount of heat passing through the heat meter within a certain period of time can be accurately calculated.