(1) Locate an optimum position where the straight pipe length is sufficient, and where pipes are in a favorable condition, e.g., newer pipes with no rust and ease of operation.
(2) Clea n any dust and rust. For a better result, polishing the pipe with a sander is strongly recommended.
(3) Apply adequate coupler to the spot where the transducers are to be installed and leave no gap between the pipe surface and the transducers.
Take care to avoid any sand or dust particles left between the pipe outer surface and the transducers.
To avoid gas bubbles inside the upper part of the pipe, the transducers should be installed horizontally by the side of the pip