What should be noted when installing an electromagnetic flowmeter?
When installing an electromagnetic flowmeter, three core aspects must be focused on: flow field conditions, installation position, and environmental interference to avoid affecting measurement accuracy. 1. Ensure stable flow field The pipeline must operate with full medium, avoiding insufficient...Read more -
Which medium cannot be measured by electromagnetic flowmeters?
Electromagnetic flowmeters are not universal; they are mainly unsuitable for low-conductivity media, media containing strong interfering components, and media exceeding the meter’s rated operating conditions. 1. Low-conductivity media Media with conductivity below the meter’s threshold (usually ...Read more -
What are the reasons for the inaccurate measurement of an electromagnetic flowmeter?
The core reasons for inaccurate measurement of electromagnetic flowmeters fall into four categories: medium state, instrument installation, equipment wear, and parameter settings. Details are as follows: 1. Medium state does not meet measurement requirements The pipeline is not fully filled with...Read more -
Level Meters: Global Applications Shaping Industries Across Continents
From the oil fields of the Middle East to the rice paddies of Southeast Asia, level meters—devices that measure the height of liquids or solids in tanks, vessels, or natural reservoirs—are indispensable tools across industries. Their ability to provide real-time data on ...Read more -
Practical Guide: Choosing the Right Open Channel Flow Meter: Factors to Consider for Weir vs. Flu...
Selecting the right open channel flow meter is critical for accurate water measurement in applications ranging from agricultural irrigation and municipal drainage to industrial wastewater management. Among the most common setups are weir and flume systems—both rely on cr...Read more -
Industry Trend: Smart Manufacturing Drives Demand—Why Electromagnetic Flow Meters Are Becoming a ...
In the era of smart manufacturing, where data-driven decision-making, real-time monitoring, and operational efficiency define industrial success, traditional process control tools are being rapidly replaced by advanced technologies. Among these, electromagnetic flow mete...Read more -
Technical Popularization: Why Do Ultrasonic Water Meters “Replace” Traditional Mechan...
In the realm of water supply and metering, traditional mechanical water meters have dominated households and industries for decades. However, as smart city construction accelerates and demands for accurate, efficient, and low-maintenance water management grow, ultrasonic...Read more -
Ultrasonic Flowmeters: Failure to Upload Data to the Central Control System?
When the measurement data of the ultrasonic flowmeter fails to be uploaded to the central control system, the problem may occur in the connection cable. Troubleshooting can be carried out from the following 4 aspects: Step 1: Check the communication cable connection. First, confirm whether the c...Read more -
Probes Easily Contaminated During Sewage Measurement?
In the sewage treatment industry, the probes of ultrasonic flowmeters are easily contaminated by impurities and oil in sewage, resulting in weakened signals and reduced measurement accuracy. The following 4-step cleaning and protection plan can be adopted: Step 1: Clean the probe regularly. It i...Read more -
Easy to Be Damaged by Freezing in Winter?
The temperature is low in winter. If the ultrasonic flowmeter is installed outdoors or on a pipeline without thermal insulation measures, it is easy to be damaged due to medium freezing. The following 5 tips can be used for anti-freezing maintenance: Tip 1: Do a good job of thermal insulation fo...Read more -
Large Fluctuations in Measurement Data?
When the measurement data of the ultrasonic flowmeter fluctuates frequently and cannot be displayed stably, the problem may occur in the following 4 dimensions, and targeted measures can be taken: Dimension 1: Installation environment interference. First, check whether the equipment is close to ...Read more -
No Display When Powered On?
During the use of ultrasonic flowmeters, many users may encounter the situation where the screen shows no response after power-on. There is no need to rush to send it back for repair; you can troubleshoot step by step as follows: Step 1: Check the power supply system. First, confirm whether the ...Read more