Portable Ultrasonic Flow Meter for HVAC and Cooling Water Systems

In HVAC and industrial cooling systems, water flow plays an important role in heat transfer and overall system performance.

Insufficient or excessive flow can affect cooling efficiency, pump operation, and energy consumption.

However, many existing systems do not have flow meters installed at every pipeline. Engineers may need to measure flow at different locations during commissioning, maintenance, or system troubleshooting.

Common Flow Measurement Challenges in HVAC Systems

Maintenance engineers often need to:

  • • Check chilled water flow in supply and return pipelines.
  • • Verify cooling water circulation.
  • • Evaluate pump performance.
  • • Investigate insufficient water flow.
  • • Compare flow rates before and after system adjustments.
  • • Check existing flow meter readings.

Installing additional inline flow meters may require draining the pipeline, modifying pipework, or shutting down part of the system.

Measure Cooling Water Flow Without Draining the Pipeline

The Lanry TF1100-EP Portable Ultrasonic Flow Meter offers a non-invasive measurement solution.

Its clamp-on sensors are installed on the outside of the pipeline, so there is no need to drain the water or cut the pipe for sensor installation.

Suitable applications include:

Chilled water circulation systems.
Cooling tower water pipelines.
Chiller inlet and outlet pipelines.
Industrial cooling water systems.
Building water circulation systems.

The instrument supports bidirectional flow measurement and can be used on a wide range of pipe diameters, depending on transducer selection.

Support HVAC Commissioning and Maintenance

With portable operation and up to 50 hours of battery life, the TF1100-EP allows engineers to check flow rates at different locations without carrying out permanent installation work.

Optional PT1000 temperature sensors can also be used for:

  • Temperature difference measurement
  • Thermal energy calculation

This provides additional information for evaluating heating and cooling system performance.

Conclusion

Whether you are commissioning a new HVAC system, checking a chilled water pipeline, or troubleshooting a cooling water circulation problem, portable ultrasonic flow measurement offers a convenient way to obtain on-site flow data.

The Lanry TF1100-EP is a practical tool for HVAC engineers, maintenance contractors, and building service professionals.


Post time: Nov-03-2026