Ultrasonic Flow Meters

20+ Years Manufacturing Experience

Portable Ultrasonic Flow Meter: The TF1100‑CH series Handheld solution


Key Highlights 

01. Non‑invasive Clamp‑on Design:

External‑mounted transducers require no pipe cutting or process shutdown; sensors never contact the measured liquid to avoid fouling risk.

02. Transit‑Time Measurement Technology:

Supports V‑method, W‑method and Z‑method installation modes, delivers high‑precision flow measurement for full closed pipelines.

03. Portable & Battery‑Powered:

Built‑in rechargeable battery provides up to 14‑hour continuous operation; lightweight unit with protective carrying case for field mobility.

04. Rich On‑board Functions:

Equipped with back‑lit 4‑line display and data‑logger, suitable for mobile spot measurement, flow calibration, data comparison and on‑site meter status verification.

05. Wide Working Range:

Bi‑directional velocity from 0.01 m/s to 12 m/s; liquid temperature coverage of ‑35 °C ~ 200 °C; compatible with clean and moderately turbid liquids (turbidity<10000 ppm).

06. Broad Liquid Compatibility:

Chemical‑resistant performance adapts to diverse media including ultrapure water, potable water, chemicals, sewage, cooling water and industrial effluent across multiple industries.

1.How Does the TF1100‑CH Series Deliver Portable Non‑Intrusive Flow Measurement?

The TF1100‑CH series is Lanry Instruments’ handheld transit‑time ultrasonic flow meter. It consists of a handheld main unit and a pair of external clamp‑on transducers. Different from inline flow meters, its transducers are strapped onto the outer surface of closed pipes without modifying pipeline structures or interrupting running processes.

Adopting advanced transit‑time principle, the two transducers work alternately as ultrasonic transmitters and receivers. Three installation configurations are optional: V‑method for twice sound travel across pipe wall, W‑method for four‑time travel, and Z‑method for one‑time cross‑pipe transmission. Users select the proper mounting mode based on actual pipe dimension and liquid properties.

The instrument calculates liquid velocity by measuring the time difference between ultrasonic pulses travelling downstream and upstream, and further computes flow rate and total flow volume. Since sensors stay outside the pipe, there is no risk of sensor fouling caused by dirty or corrosive media. Powered by rechargeable battery and housed in a compact portable case, the TF1100‑CH is well‑suited for temporary field measurement tasks.

2. What Core Functions Make TF1100‑CH Fit for Field‑Site Work?

Feature Specification / Description
Power Supply Rechargeable battery with up to 14‑hours continuous working time
Display Back‑lit 4‑line LCD display for on‑site reading
Data Storage Built‑in data logger for recording measurement history
Velocity Range 0.01 m/s ~ 12 m/s, bi‑directional flow measurement
Liquid Temperature ‑35 °C ~ 200 °C
Liquid Turbidity Works for clean to moderately dirty liquids, turbidity <10000 ppm
Transducer Type Non‑invasive external clamp‑on transducers
Installation Modes V‑method / W‑method / Z‑method selectable
Main Application Mobile measurement, flow calibration, data comparison, running status inspection
Transport Light‑weight design, supplied with protective portable carrying case

The TF1100‑CH is purpose‑built for spot checking and validation instead of permanent fixed monitoring. Operators can carry the whole kit to different measuring points, clamp transducers onto pipe outer wall, finish parameter configuration and obtain flow data quickly without any pipe alteration.

3. What Application Scenarios Is the TF1100‑CH Series Suitable For?

Benefiting from its clamp‑on portable transit‑time technology, the TF1100‑CH solves measuring challenges where installing permanent inline meters is inconvenient or uneconomical.

Application Description
Water & Wastewater Industry Flow spot‑check for various process liquid pipelines
Petrochemical Industry Measuring alcohol, acid solutions, thermal oil and other chemical fluids
Chemical Industry Field inspection for refrigeration and air‑conditioning circulating pipelines
HVAC & Refrigeration Non‑intrusive spot measurement for hygienic process pipelines
Food, Beverage & Pharmaceutical Thermal power, hydropower and nuclear plant feed‑water & auxiliary pipeline verification
Power Plants On‑site flow survey for industrial process pipelines
Metallurgy & Mining Pipeline leak investigation, periodic inspection, flow data collection and comparison
General Plant Engineering explosion‑proof version available for hazardous area applications

Note: TF1100‑CH transit‑time handheld flow meter is designed for full‑pipe closed pipeline applications. It is not applicable for open channels or partially‑filled pipes. For open‑flow scenarios, Lanry DOF6000 series area‑velocity flow meter shall be adopted as alternative solution.

4. How to Choose Between TF1100‑CH and DOF6000 Series?

Feature TF1100‑CH DOF6000 Series
Measurement Principle Transit‑time ultrasonic Doppler area‑velocity
Pipe Condition Full closed pipe only Open channel / partially‑filled pipe
Sensor Installation Clamp‑on outside pipe, no media contact Submerged sensor immersed inside water
Typical Use Portable spot‑check, calibration for full‑pipe lines Long‑term or temporary monitoring for rivers, channels, culverts
Key Measured Value Flow rate, total flow Velocity, depth, conductivity, flow rate, total flow
Representative Models TF1100‑CH DOF6000‑W (wall‑mounted), DOF6000‑P (portable)

 

Users need to confirm actual pipe status before selection. If the pipeline always keeps full liquid, TF1100‑CH provides convenient portable clamp‑on measurement. For open channels, rivers or non‑full pipes, DOF6000 series is the correct product choice.

5. What Makes TF1100‑CH a Reliable Portable Flow‑Measuring Tool?

The TF1100‑CH handheld ultrasonic flow meter combines transit‑time measuring performance and high field‑operability. Its non‑intrusive external transducer setup removes the requirement to cut or modify existing pipes. The rechargeable battery, data‑logging capability and wide media adaptability support diverse on‑site tasks including spot survey, flow calibration and meter performance verification.

With flexible V/W/Z installation modes and broad temperature & flow range, this portable unit delivers dependable measurements for water‑treatment, chemical, power, petrochemical and many other sectors. It serves as a practical auxiliary instrument for professionals conducting periodic flow inspection and field‑site diagnostic work on full‑pipe liquid pipelines.

FAQ About the Electromagnetic Flowmeter

Q1. Does TF1100‑CH need to cut the pipeline during installation?

No. The TF1100‑CH uses clamp‑on external transducers. You only need to strap sensors onto the outer pipe surface. No pipe cutting or process interruption is required.

Q2.Can TF1100‑CH measure partially‑filled pipes or open channels?

No. The TF1100‑CH transit‑time flow meter works only for full‑pipe closed pipelines. For partially‑filled pipes and open‑flow conditions, please select Lanry DOF6000 series.

Q3. What is the maximum continuous working time for TF1100‑CH on battery?

The built‑in rechargeable battery supports up to 14 hours of continuous field measurement.

Q4. What liquid turbidity can TF1100‑CH handle?

It works for clean and moderately dirty liquids with turbidity below 10000 ppm. Heavily turbid media may cause signal attenuation and affect measuring stability.

Q5. What installation modes are available for TF1100‑CH transducers?

Three modes are selectable: V‑method, W‑method and Z‑method. Users shall choose according to pipe diameter and wall‑thickness parameters.

1
Arina Hu | Sales Engineer

Graduating with a Bachelor’s in Business English, as a sales engineer of Lanry Instruments more than 5 years.

Having participated in multiple overseas exhibitions,possess in-depth product knowledge of our complete instrument lineup

and strong capabilities for international client engagement.Should you have any project demands for instruments, pls feel free to contact me.


Post time: Sep-15-2026

Send your message to us: