PTFE vs. FEP Lining: Which Is Better for Mag-11 Electromagnetic Flow Meters?

ENGINEERING SELECTION GUIDE

PTFE vs. FEP Lining: Which Is Better for Mag-11 Electromagnetic Flow Meters?

Compare chemical resistance, temperature range and pressure suitability to pick the right liner.

1. What Are PTFE and FEP Linings?

PTFE (Polytetrafluoroethylene) and FEP (Fluorinated Ethylene Propylene) are fluoropolymer materials widely used in electromagnetic flow meter linings because of their excellent chemical resistance.

PTFE

PTFE provides excellent resistance to a wide range of chemical media, including many strong acids and alkalis. It is commonly selected for industrial applications where chemical stability and corrosion protection are important.

FEP

FEP also offers excellent chemical resistance, comparable to PTFE. For the Mag-11 electromagnetic flow meter, FEP is particularly recommended for certain special operating conditions, especially pipelines operating under negative pressure.

When selecting an electromagnetic flow meter, the lining material is an important factor affecting measurement reliability and service life. This is especially true when measuring corrosive liquids, industrial wastewater, and other special conductive media.

PTFE and FEP are two commonly used fluoropolymer lining materials for electromagnetic flow meters. Both offer excellent chemical resistance, but their applicable conditions are not exactly the same.

So, what are the differences between PTFE and FEP lining? And how should you choose the right option for the Lanry Mag-11 electromagnetic flow meter?

Mag-11

2. PTFE vs. FEP: Key Differences in Mag-11 Electromagnetic Flow Meter

Although PTFE and FEP have similar chemical resistance, their applicable pipe sizes and operating conditions differ.

Comparison PTFE Lining FEP Lining
Chemical resistance Excellent Comparable to PTFE
Working temperature -40 to 110°C -40 to 140°C
Negative-pressure applications Not recommended in the selection table Recommended
Typical applications Corrosive liquids and selected sanitary applications Corrosive liquids and special operating conditions

The temperature and diameter ranges above are based on the Mag-11 electromagnetic flow meter lining selection documentation. Actual availability should be confirmed according to the required meter configuration.

3. When Should You Choose PTFE Lining?

PTFE Lining – Where It Fits

PTFE is a suitable choice for applications requiring excellent chemical resistance. It can handle a wide range of chemical media and is commonly considered for industrial processes involving corrosive liquids.

For the Mag-11 electromagnetic flow meter, PTFE can be considered for:

✓ Strong acids and alkalis.

✓ Corrosive industrial liquids.

✓ Applications with sanitary requirements.

✓ Processes requiring high chemical stability.

Limitation: PTFE is not suitable for every operating condition. The selection documentation excludes negative-pressure pipeline applications and media requiring good wear resistance from its stated PTFE applicable range.

Therefore, pipeline pressure and the presence of solid particles should be considered before selecting a PTFE‑lined electromagnetic flow meter.

4. When Should You Choose FEP Lining?

FEP Lining – Where It Fits

FEP offers chemical resistance comparable to PTFE, with a specified working temperature range of -40 to 140°C in the Mag-11 electromagnetic flow meter technical documentation.

One important advantage in the Mag-11 lining selection guide is its recommendation for negative-pressure applications. This makes FEP a suitable option for certain pipeline conditions where PTFE is not recommended.

FEP can also be considered for:

✓ Corrosive conductive liquids.

✓ Applications with sanitary requirements.

✓ Pipelines operating under negative pressure.

✓ Media prone to scaling, such as paper pulp.

Note: The Mag-11 documentation also mentions FEP for certain wearing media, such as slurry and pulp. However, its performance table excludes wearing media such as mortar from the stated FEP applicable range. The actual solids content and abrasion conditions should therefore be evaluated carefully.

5. How to Select the Right Lining for Mag-11 Electromagnetic Flow Meter?

Key Checkpoints for PTFE / FEP Selection

Choosing between PTFE and FEP requires more than comparing their chemical resistance. The actual operating conditions should also be considered.

Check the Chemical Composition

Identify the liquid being measured, including its chemical components and concentration. Confirm that the selected lining is compatible with the medium.

Check the Operating Temperature

According to the Mag-11 electromagnetic flow meter technical documentation. PTFE: -40 to 110°C and FEP: -40 to 140°C.
For high-temperature media at or above 140°C, the Mag-11 selection guide recommends considering PFA lining, which has a specified working temperature range of -40 to 180°C.

Check the Pipeline Pressure

If the pipeline may operate under negative pressure, FEP should be considered according to the Mag-11 lining selection recommendations.

Consider Solid Particles and Abrasion

If the medium contains solid particles, check whether they may cause wear to the lining. For abrasive media such as slurry and pulp, the Mag-11 selection guide also identifies PU or FEP as options. However, the specific medium and operating conditions must be checked against the applicable range of each material.

6. Mag-11 Electromagnetic Flow Meter: Flexible Lining Options

The Lanry Mag-11 electromagnetic flow meter is designed to measure the volumetric flow of conductive liquids with conductivity greater than 5 μS/cm. It can be used for industrial water, wastewater, corrosive liquids, mud, and paper pulp.

The Mag-11 electromagnetic flow meter series offers several lining options to meet different application requirements.

Main Features:

•
Pipe size: DN10–DN2000 for flange-type models.
•
Lining materials: Ne, FEP, PTFE, PU, and PFA.
•
Conductivity: Suitable for conductive liquids above 5 μS/cm.
•
Measures general conductive liquids and liquid‑solid two‑phase suspensions.
•
Accuracy: Can reach ±0.2%, depending on configuration.
•
No moving parts and no pressure loss.
•
Optional 4–20mA output, pulse output, RS485 communication, Bluetooth, and other functions depending on configuration.

With multiple lining and electrode material options, Mag-11 electromagnetic flow meter can be configured for different industrial flow measurement requirements.

7. Frequently Asked Questions

Is PTFE more corrosion-resistant than FEP?

According to the Mag-11 electromagnetic flow meter technical documentation, FEP has chemical resistance comparable to PTFE. Both materials are suitable for many corrosive liquid applications, subject to chemical compatibility.

What is the working temperature of PTFE and FEP in Mag-11 electromagnetic flow meter?

PTFE: -40 to 110°C · FEP: -40 to 140°C

Which lining is recommended for negative-pressure pipelines?

The Mag-11 electromagnetic flow meter lining selection guide recommends FEP for negative-pressure applications.

How do I choose between PTFE and FEP lining?

Consider the chemical composition, operating temperature, pipeline pressure, pipe size, and solids content. PTFE is suitable for a wide range of corrosive liquids, while FEP is specifically recommended for negative-pressure applications in the Mag-11 electromagnetic flow meter selection guide.

Sabrina Liu, Sales Engineer at Lanry Instruments

TALK TO OUR ENGINEER
Sabrina Liu · Sales Engineer

Hello, I’m Sabrina Liu, a Sales Engineer at Lanry Instruments. With three years of experience in the flow measurement industry, I help customers find the right measurement solutions for their applications. I’m familiar with our range of ultrasonic flow meters, electromagnetic flow meters, water meters, and level meters. Whether you need product information, technical support, or help choosing the right instrument for your project, I’m happy to assist. Feel free to contact me on WhatsApp!