Insertion Transducer On-Line Quick Install Instruction–For General Insertion Transducers
Insertion Transducer Installation Manual 1. Locate the Installing Point on Pipe 2. Weld Mounting Base 3. Place the Gasket Ring PTFE Gasket ring o...Read more -
Working principle and application of Doppler flow meter
Doppler ultrasonic flowmeter uses the physics of the Doppler effect, in any liquid flow in the presence of discontinuity will be reflected ultrasonic signal frequency shift (that is, signal phase difference), by measuring the phase difference, the flow rate can be measur...Read more -
The principle and application of transit-time ultrasonic flow meter?
A transit-time difference type ultrasonic flowmeter is measured using A pair of transducers (sensors A and B in the figure below), which alternately (or simultaneously) transmit and receive ultrasonic waves. The signal travels faster upstream than upstream in the fluid, ...Read more -
What is difference between reading accuracy and FS accuracy of the flow meter?
The reading accuracy of the flowmeter is the maximum allowable value of the relative error of the instrument, while the full scale accuracy is the maximum allowable value of the reference error of the instrument. For example, the full range of the flowmeter is 100m3/h, when the actual flow is 10...Read more -
What are the main advantages of ultrasonic flowmeters?
1). Online and hot-tapped installation, no pipe cutting or processing interrupt. 2). The clamp-on sensors are easy to install, it can be installed even at high pipe pressure. 3). The clamp on sensor flowmeter is not in direct contact with the measuring medium. It can measure all kinds of conv...Read more