-
Advantages of high-precision ultrasonic flow meter
External clamp on ultrasonic flow meter can realize non-contact flow measurement, even if it is insertion ultrasonic flow meter,it is almost zero pressure lose; The cost of ultrasonic flow meter is almost irrelevant to the pipe diameter, it is very big advantage to choose flow meter for large d...Read more -
When you are hesitating to use electromagnetic flow meter or ultrasonic flow meter, you can refer to below of the following aspects .
1. Liquid properties If the liquid cannot electricity conductivity, the only one selection is ultrasonic flow meter . 2. On-site environment Generally, ultrasonic flow meter is susceptible to electromagnetic wave interference. If there is an object which emits electromagnetic wave on site, it ...Read more -
What are typical applications for transit time ultrasonic flowmeters?
Our clamp on ultrasonic flow meter transit time can measure water flow, heat function and temperature measurement are optional with PT1000 sensors. 1. Water, sea water, pure water 2. HVAC Airconditioning 3. Municipal Water 4. Liquid flow system checking 5. Chemical liquids 6. Semiconductor and El...Read more -
Accuracy Considerations-DOF6000 open channel flow meter
Alignment with Flow and Depth For the calibration to be valid, the transducer needs to be horizontally and vertically aligned with the flow. While Ultraflow QSD 6537 instruments are calibrated pointing into the flow, they can be pointed downstream with little loss of calibration accuracy. You may...Read more -
FREQUENTLY ASKED QUESTIONS AND ANSWERS for TF1100 serial transit time ultrasonic flow meter
Q: New pipe, high quality material, and all installation requirements met: why still no signal detected? A: Check pipe parameter settings, installation method and wiring connections. Confirm if the coupling compound is applied adequately, the pipe is full of liquid, transducer spacing agrees with...Read more -
Lanry Relay output introduction
(If portable flow meter needs this functionality, please make a statement when placing orders) Please refer to 4.3.14 Dual Relay Configuration to see Menu Configuration. The relay operations are user configured via the front panel to act in flow rate alarm or error alarm, power supply interruptio...Read more -
TRANSDUCER CABLES
After the transducers A and B inserting into the pipe, the sensor cables should be routed to the transmitter location. Verify that the supplied cable length is sufficient to meet the installation requirements. While transducer cable extension is not generally recommended, if additional transducer...Read more -
What are the problems maybe occur there during the measurement?
1. Readings are erratic and change dramatically, 2. Reading is not accurate and have a big error . 3. Ultrasonic flowmeter sensors are good, but the flow rate is low or no flow rate 4. The measured medium is pure or solid suspended matter too low 5. The coupling between the sensor and the pipelin...Read more -
What is the difference of clamp on ultrasonic flowmeter, inline ultrasonic water meter, insertion ultrasonic flowmeter ?
Different types meter have different advantages . 1 Clamp on ultrasonic flow meter No need to cut the pipe and interrupt process ; Clamp on transducers are just clamped on pipe wall, easy to install ; 2.Inline ultrasonic water meter It can measure the pipe of sparse material , poor acoustic cond...Read more -
Why does clamp on ultrasonic flow meter show weak signal when during flow measurement ?
Clamp on ultrasonic flow meter is suitable for flow measurement in full water pipe, it is easy to install and no contact with liquid directly; It can measure the medium that is not easy to touch or observe. Usually, ultrasonic flowmeter clamp on can work for very long time. When the poor signal...Read more -
What is the class of ultrasonic water meter ?
Water meter’s accuracy is graded for Class 1 and 2. 1) Class 1 water meters (only applicable to Q3≥100m3/h water meters) in the water temperature range from 0.1℃ to 30℃, the maximum allowable error of water meters in the high zone (Q2≤Q≤Q4) is ±1%; The low area (Q1≤Q < Q2) was ±3%. ...Read more -
Advantages and Disadvantages of Doppler Flowmeters
Although Doppler ultrasonic flowmeter is not so accurate as transit time ultrasonic flow meters, Doppler flowmeter can measure dirty liquids ( but it cannot measure clean liquids ), Doppler flow meter can measure sewage flow because sewage is with a lot of solids, at the same time, it is also mea...Read more



